Agilent Technologies ENA Series User Manual page 416

Rf network analyzer
Hide thumbs Also See for ENA Series:
Table of Contents

Advertisement

Softkey Functions
Analysis Menu
Key Operation
(Continued)
Fixture Simulator
Port Matching
Select Circuit
Adds a user-defined matching circuit to the port selected in the
User
menu. The user-defined matching circuit must be prepared in the 2-port
Touchstone data format and loaded onto the E5070A/E5071A from the
menu.
File
Returns to the softkey display screen one level higher.
Cancel
Sets the value of C for the matching circuit selected in the
C
menu for addition to the port selected in the
Sets the value of G for the matching circuit selected in the
G
menu for addition to the port selected in the
Sets the value of L for the matching circuit selected in the
L
menu for addition to the port selected in the
Sets the value of R for the matching circuit selected in the
R
menu for addition to the port selected in the
Opens a dialog box for loading a user-defined 2-port Touchstone data file.
User File
The loaded matching circuit can be added to ports by selecting
Select Circuit
Returns to the softkey display screen one level higher.
Return
Displays softkeys for setting up the port impedance conversion function. This function is included in internal
Port ZConversion
software that converts S parameters determined with a 50 W reference port impedance to S parameters for
arbitrary port impedance.
Enables or disables the port impedance conversion function.
Port
ZConversion
Sets the reference impedance of port 1.
Port 1 Z0
Sets the reference impedance of port 2.
Port 2 Z0
Sets the reference impedance of port 3.
*1
Port 3 Z0
*2
Sets the reference impedance of port 4.
Port 4 Z0
Returns to the softkey display screen one level higher.
Return
Displays softkeys for setting up the network de-embedding function. Network de-embedding is a function used to
De-Embedding
eliminate any user-defined network (with a reference impedance of 50 W) supplied in a 2-port Touchstone data
file, from desired test ports to extend the calibration plane.
Enables or disables the network de-embedding function.
De-Embedding
Displays softkeys for selecting test ports for which network de-embedding will be performed.
Select Port
Selects test port 1 for performing network de-embedding.
1
Selects test port 2 for performing network de-embedding.
2
Selects test port 3 for performing network de-embedding.
*1
3
*2
Selects test port 4 for performing network de-embedding.
4
Returns to the softkey display screen one level higher.
Cancel
408
Function
Select Port
Select Port
Select Port
Select Port
menu.
SCPI Command
:CALC{1-9}:FSIM:SEND:PMC:
Select Port
PORT{1-4} USER
User
:CALC{1-9}:FSIM:SEND:PMC:
Select Circuit
PORT{1-4}:PAR:C
menu.
:CALC{1-9}:FSIM:SEND:PMC:
Select Circuit
PORT{1-4}:PAR:G
menu.
:CALC{1-9}:FSIM:SEND:PMC:
Select Circuit
PORT{1-4}:PAR:L
menu.
:CALC{1-9}:FSIM:SEND:PMC:
Select Circuit
PORT{1-4}:PAR:R
menu.
:CALC{1-9}:FSIM:SEND:PMC:
PORT{1-4}:USER:FIL
in the
User
:CALC{1-9}:FSIM:SEND:ZCON: STAT
:CALC{1-9}:FSIM:SEND:ZCON:
PORT1:Z0
:CALC{1-9}:FSIM:SEND:ZCON:
PORT2:Z0
:CALC{1-9}:FSIM:SEND:ZCON:
PORT3:Z0
:CALC{1-9}:FSIM:SEND:ZCON:
PORT4:Z0
:CALC{1-9}:FSIM:SEND:DEEM:STAT
:CALC{1-9}:FSIM:SEND:DEEM:
PORT1
:CALC{1-9}:FSIM:SEND:DEEM:
PORT2
:CALC{1-9}:FSIM:SEND:DEEM:
PORT3
:CALC{1-9}:FSIM:SEND:DEEM:
PORT4
Appendix D