Agilent Technologies ENA Series User Manual page 484

Rf network analyzer
Hide thumbs Also See for ENA Series:
Table of Contents

Advertisement

Replacing the 8753ES with the E5070A/E5071A
Comparing Functions
Table F-5
Functions of the 8753ES vs. the E5070A/E5071A
Function
Status report Register types
For limit test
Save/Recall
Storage
Storage initialization
Save only
Object to be saved/recalled
File formats
Format for saving the screen display
File manipulation
Macros
Creating macros
Automatic execution
System
Self-test
Internal clock
Beep sound
Measuring instrument mode
476
8753ES
Status byte register
Service request enable register
Standard event status register
Standard event status register B and
enable register
Included in the standard event status
register B and validation register
Internal registers
Internal disk (floppy disk)
External disk (connected through
GPIB)
Possible
LCD screen image
Instrument State (You can
simultaneously save formatted data
array for the active trace, raw data
array, corrected data array, and LCD
images.)
Color settings
Test sequence
Binary form, ASCII form
JPEG format
Reading file information
Deleting a file
Uses a test sequence.
Will execute if "AUTO" is given as
the name of the sequence 6.
Can be executed by using the front
panel and SCPI commands.
Available
On/Off setting definable for
completion of actions, warnings, and
limit test failures
Can be selected from a standard
network analyzer, external signal
source (automatic), external signal
source (manual), and tuned receiver.
E5070A/E5071A
Status byte register
Service request validation register
Standard event status register
Operation status register and
validation register
Questionable status register and
validation register
Questionable limit status register
Questionable limit status channel
register
Internal hard disk
Floppy disk
Available with mouse
Formatted data array
LCD screen image
Instrument State (You can
simultaneously save formatted data
array for the active trace and
calibration data.)
Segment sweep table
Limit line table
VBA project
Binary form
Ò
Windows
Bitmap format, PNG
format
Reading file information
Deleting a file or folder
Creating a folder
Copying a file
Uses VBA.
Only auto loading is possible.
Can be executed by using the front
panel.
Available
On/Off setting definable for
completion of actions and warnings
Always a network analyzer
Appendix F

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

E5070E5071a

Table of Contents