ACX Series Universal Access Router Configuration Guide
Configuring a PTP Master Boundary Clock Interface
246
[edit protocols ptp master]
user@host# set max-delay-response-interval max-delay-response-interval-value
(Optional) Specify the maximum log mean interval between synchronization
7.
messages—from
through
–7
[edit protocols ptp master]
user@host# set max-sync-interval max-sync-interval-value
(Optional) Specify the minimum log mean interval between announce messages—from
8.
through
. The default value is
–0
4
[edit protocols ptp master]
user@host# set min-announce-interval min-announce-interval
(Optional) Specify the minimum log mean interval between delay-response
9.
messages—from
–7
through
[edit protocols ptp master]
user@host# set min-delay-response-interval min-delay-response-interval
(Optional) Specify the minimum log mean interval between synchronization
10.
messages—from
through
–7
[edit protocols ptp master]
user@host# set min-sync-interval min-sync-interval-value
(Optional) Specify the log mean interval between synchronization messages—from
11.
through
. The default value is
–7
4
clients. The master boundary clock sends synchronization messages to manual clock
clients as specified in the
[edit protocols ptp master]
user@host# set sync-interval sync-interval-value
After you have configured the PTP master boundary clock parameters, enter the
command from configuration mode. To complete the configuration of the master
boundary clock, complete
page
246.
After you have configured the master boundary clock parameters, complete the
configuration of the master boundary clock by configuring an interface to act in the role
of the master clock.
To configure a PTP master boundary clock interface:
Configure the interface on which to respond to downstream PTP slaves or clients.
1.
[edit protocols ptp master]
user@host# edit interface interface-name
. The default value is
4
.
0
4
. The default value is
. The default value is
4
. This configuration is used for manual clock
–6
syn-interval-value
statement.
"Configuring a PTP Master Boundary Clock Interface" on
.
4
–7
.
.
–7
Copyright © 2017, Juniper Networks, Inc.