Routers - Juniper ACX1000 Configuration Manual

Junos os; acx series universal access router
Hide thumbs Also See for ACX1000:
Table of Contents

Advertisement

Related
Documentation
Example: Ethernet Ring Protection Switching Configuration on ACX Series Routers
Requirements
Copyright © 2017, Juniper Networks, Inc.
east-interface {
control-channel channel-name {
ring-protection-link-end;
}
west-interface {
node-id mac-address;
control-channel channel-name {
ring-protection-link-end;
}
data-channel {
vlan number;
}
guard-interval number;
restore-interval number;
}
}
For each ring, a protection group must be configured. There may be several rings in each
node, so there should be multiple protection groups corresponding to the related Ethernet
rings.
Three interval parameters (
configured at the protection group level. These configurations are global configurations
and apply to all Ethernet rings if the Ethernet ring doesn't have a more specific
configuration for these values. If no parameter is configured at the protection group level,
the global configuration of this parameter uses the default value.
Ethernet Ring Protection Switching Overview on page 111
Understanding Ethernet Ring Protection Switching Functionality on page 112
Example: Ethernet Ring Protection Switching Configuration on MX Routers
Example: Configuring Ethernet Ring Protection Switching on EX Series Switches
Ethernet Interfaces Feature Guide for Routing Devices
This example describes how to configure Ethernet ring protection switching on an ACX
Series router:
Requirements on page 119
Ethernet Ring Overview and Topology on page 120
Configuring a Three-Node Ring on page 120
This example uses the following hardware and software components:
Router node 1 running Junos OS with two Gigabit Ethernet interfaces.
Router node 2 running Junos OS with two Gigabit Ethernet interfaces.
Chapter 4: Configuring Interfaces and Chassis
,
restore-interval
guard-interval
, and
) can be
hold-interval
119