Analog Inputs As Digital Inputs - Siemens SINAMICS G110M Operating Instructions Manual

Distributed converter for simogear geared motors
Hide thumbs Also See for SINAMICS G110M:
Table of Contents

Advertisement

Example
To switch on the motor using digital input DI 2, you must connect the status parameter of DI 2
with p0840: Set p0840 = 722.2
Parameter
Table 8-3
BI
p0810 Command data set selection CDS bit 0
p0840 ON/OFF1
p0844 OFF2
p0848 OFF3
p0852 Enable operation
p0855 Unconditionally open holding brake
p0856 Enable speed controller
p0858 Unconditionally close holding brake
p1020 Fixed speed setpoint selection, bit 0
p1021 Fixed speed setpoint selection, bit 1
p1022 Fixed speed setpoint selection, bit 2
p1023 Fixed speed setpoint selection, bit 3
p1035 Motorized potentiometer setpoint higher
A complete list of the binector inputs is provided in the List Manual.
Further information
You can debounce the digital input signal using parameter p0724.
Additional information is provided in the parameter list and function diagrams 2210 ff.
8.4.2

Analog inputs as digital inputs

Function description
Distributed converter for SIMOGEAR geared motors
Operating Instructions, 10/2020, FW V4.7 SP13, A5E31298649B AL
p0840
722.2
Binector inputs (BI) of the converter (selection)
Meaning
Manuals and technical support (Page 415)
1
BI: pxxxx
2
7
8
r0722.11
3
6
4
5
r0722.12
8.4 Adapt the default setting of the inputs and outputs
BI
Meaning
p1036 Motorized potentiometer setpoint lower
p1055 Jogging bit 0
p1056 Jogging bit 1
p1113 Setpoint inversion
p1201 Flying restart enable signal source
p2103 1. Acknowledge faults
p2106 External fault 1
p2112 External alarm 1
p2200 Technology controller enable
p3330 2-3-WIRE control command 1
p3331 2-3-WIRE control command 2
p3332 2-3-WIRE control command 3
Advanced commissioning