Fiat 1996 Brava Service Manual page 592

Table of Contents

Advertisement

Bravo-Brava
98 range
Auxiliary units
Manually operated climate control
50.
Any time the compressor is removed or moved, it should be positioned with the cover fac­
ing upwards as illustrated in fig. 7 to prevent oil leaks and the fouling of the
compressor.
P4A21CH02
P4A21CH03
Before carrying out operations which could cause the escape of refrigerant fluid, the air condi­
tioning system must be drained. Protective gloves and goggles should be worn during this op­
eration.
In order to facilitate the draining operation, the engine and the system should be left to run for at
least 10-15
minutes.
N O T E
If the O-ring seals are being replaced, use green or black coloured seals, making sure that they
are current production
ones which are resistant to R134A fluid. Do not, under any
circum­
stances, use old production
black seals because they are permeable.
N O T E
If the system pipes are dismantled, it is advisable to seal the disconnected
ends of the pipes
with suitable plugs if they are not going to be refited immeidately to prevent dampness or for­
eign bodies from
entering.
\
^Y
Y
/$
/ ^ s \
/w
X^\ \ \Vr
&y
N
/ /
tet
WA
Connecting the equipment to the vehicle air
conditioning system
Carry out the following operations in order:
- Check that the equipment taps are closed
and that the electrical control knobs are in
position 0 (off), then engage the connector
for the light blue flexible pipe w i t h the nee­
dle valve on the section of pipe w h i c h con­
nects the evaporator to the compressor.
P4A21CH04