Fiat 1996 Brava Service Manual page 587

Table of Contents

Advertisement

Auxiliary units
Climate control
Bravo-Brava
98 range
50.
LOCATION OF CLIMATE CONTROL SYSTEM COMPONENTS
The climate control system consists of the following components:
- a variable flow rate compressor (SKROLkfor 1242 16v and 1910 JTD versions - NIPPONDENSO TV
12SC for other versions) which is fixed to the engine by brackets;
- a condenser which is a heat exchanger fitted in front of the engine coolant radiator;
- a drier filter which is located near the left side of the condenser;
- an evaporator which is the second heat exchanger for the system and is located in the above men­
tioned assembly;
- an expansion valve which is fitted on the evaporator inlet duct;
- various rigid and flexible pipes which connect the various system components;
- a threee stage pressure switch which is fitted on the drier filter.
There are two small pipes, fitted to the high and low pressure pipes, with a needle valve which is de­
signed to drain and repressurize the system.
P4A16CH01
1. Compressor
2. Condenser
3. Drier filter
4. Evaporator
5. Expansion valve
6. Pipe between compressor and condenser
7. Pipe between condenser and drier filter
8. Pipe between filter and evaporator
9. Pipe between evaporator and compressor
10. Three stage pressure switch
11. Needle valve for draining the system (low
pressure side)
12. Needle valve for draining and repressurizing
the system (high pressure side)
16
Print no.
506.670/76