MFE Type
This field only appears when Incoming Call Type is mfe.
Valid entries
2/5
2/6
Outgoing Call Type
This field defines the signal type that the PBX uses to place an outgoing call into a CO.
Valid entries
group-ii-mfc
mfe
none
Outgoing Forward Signal Absent Timer (sec)
This field appears only when the content of Outgoing Call Type is group-ii-mfc.
Valid entries
11 to 255
Usage
Determines which public signaling Communication Manager will use.
Usage
If the content of this field is group-ii-mfc, the system displays the third
page of the screen. The third page displays entries for all group-I, group-II
group-A, and group-B signal types with a set of default values.
Use only in Spain (multi-frequency Espanol)
If the content of this field is none, the system does not display the third
page. In addition, Outgoing Forward Signal Present Timer, Outgoing
Forward Signal Absent Timer, ANI Prefix, ANI for PBX, Next ANI
Digits, and Collect All Digits Before Seizure will not display on field
descriptions for page 1.
Usage
Enter the maximum number of seconds to elapse between forward
signals on outgoing calls. The timer starts (and restarts) when a forward
tone is taken off the link and it stops when the next forward tone is applied
to the link.