Screen Reference
(Time Warning) Extension
Appears if the Queue field is y. An extension is needed when an x is placed in Time Warning
Port. This extension can be used by the Terminal Translation Initialization (TTI) feature to
assign a port to this extension from the port itself. Once Time Warning Port is assigned a valid
port (either via TTI or the change hunt-group command), then the extension is removed and
considered unassigned.
Valid entries
Extension
(Time Warning) Port
Appears if the Queue field is y. Enter the seven-character port number assigned to the Auxiliary
Queue Time Warning lamp that flashes when the time entered in Time Warning Threshold has
been reached by a call in queue.
Note:
This port is assigned to an Analog Line circuit pack or given an X designation if
Note:
an extension is used. Enter the necessary characters.
Valid entries
01 to 03 (DEFINITY CSI) or
1 to 64 (S8700/S8300 Media Servers)
A to E
0 to 20
01 to 04 (Analog TIE trunks)
01 to 31
For example, 01A0612 is in cabinet 01, carrier A, slot 06, and circuit number (port) 12.
TN
Valid entries
1 to 100
1092 Administrator Guide for Avaya Communication Manager
Usage
Enter an unassigned extension. This field cannot be blank.
Usage
First and second characters are the cabinet number
Third character is the carrier
Fourth and fifth character are the slot number
Six and seventh characters are the circuit number
Usage
Enter the Tenant Partition number.