Avaya Communication Manager Administrator's Manual page 1658

Hide thumbs Also See for Communication Manager:
Table of Contents

Advertisement

Screen Reference
Incoming Disconnect (msec)
The field appears only when the Direction field is incoming or two-way and the Trunk Type
field is either blank or cont.
Valid entries
50 to 2550 in
increments of 10
Incoming Disconnect Send (msec)
This field is only administrable if the Trunk Type field is dis and the trunk group Direction field
is incoming or two-way. Only TN2140 ports receive this timer.
Valid entries
500 to 1200 in
increments of 100
Incoming Glare Guard (msec)
This field only appears when the trunk group Direction field is two-way.
Valid entries
100 to 25500 in
increments of
100
Incoming Incomplete Dial Alarm (sec)
Only the TN436 (all), TN459 (all), TN464C (or later), TN767, TN2140, TN2146, TN2184,
TN2199, and TN2242 circuit packs use this timer.
Valid entries
1 to 255 in
increments of 1
1658 Administrator Guide for Avaya Communication Manager
Usage
Enter the minimum valid duration of a disconnect signal for an incoming
call. Avaya Communication Manager will not recognize shorter
disconnect signals. This field cannot be blank. For Brazil pulsed E&M
signaling, use 600.
Usage
Enter the duration of the backward release signal your server running
Communication Manager sends at the end of an incoming call.
Usage
Enter the minimum interval that must elapse between a trunk's release
from an incoming call and its seizure for an outgoing call. This field cannot
be blank. This delay gives the far-end time to release all equipment after
the trunk is released.
Usage
Enter the maximum acceptable interval between an incoming seizure and
receipt of all digits. Intervals greater than this limit generate an inline error.