Screen Reference
Outgoing Dial Guard (msec)
Valid entries
100 to 25500
in increments
of 100
Outgoing Disconnect (msec)
Valid entries
50 to 2550 in
increments of 10
Outgoing Disconnect Send (msec)
This field is administrable only if the Trunk Type field is dis and the trunk group Direction field
is two-way or outgoing. Only TN2140 ports receive this timer.
Valid entries
100 to 9900 in
increments of 100
Outgoing End of Dial (sec)
This field controls firmware answer supervision timers on circuit packs that have them. It
appears when the Direction field is outgoing or two-way and the Receive Answer
Supervision field is n. If the Receive Answer Supervision field is y, this field does not appear
and the firmware timer on the appropriate circuit pack is automatically disabled.
1660 Administrator Guide for Avaya Communication Manager
Usage
Enter the minimum interval between seizure acknowledgment of a trunk and
the outpulsing of digits. This field cannot be blank. For trunks that do not
provide seizure acknowledgment, the timer specifies the minimum time
between seizure and the outpulsing of digits. Any digit the caller dials after
they lift the receiver, but before the timer expires, is not outpulsed until the
timer expires.
Usage
Enter the minimum valid duration of a disconnect signal for an outgoing
call. Communication Manager will not recognize shorter disconnect
signals. This field cannot be blank. This timer begins timing when a
disconnect signal is detected on an outgoing call and resets when the
signal is no longer detected. If the timer expires, the trunk drops. For
Brazil pulsed E&M signaling, use 600.
Usage
Enter the duration of the forward release signal your server running
Communication Manager sends at the end of outgoing calls.