Avaya Communication Manager Administrator's Manual page 883

Hide thumbs Also See for Communication Manager:
Table of Contents

Advertisement

Valid entries
Usage
data-line
Assigns a Data Line Data Module. The Data Line Data Module (DLDM)
screen assigns ports on the Data Line circuit pack (DLC) that allows EIA
232C devices to connect to the system. The DLC, with a companion
Asynchronous Data Unit (ADU), provides a less expensive data interface
to the system than other asynchronous DCP data modules.
The DLC supports asynchronous transmissions at speeds of Low and
300, 1200, 2400, 4800, 9600, and 19200 bps over 2-pair (full-duplex)
lines. These lines can have different lengths, depending on the
transmission speed and wire gauge.
The DLC has 8 ports. The connection from the port to the EIA device is
direct, meaning that no multiplexing is involved. A single port of the DLC
is equivalent in functionality to a data module and a digital line port. The
DLC appears as a data module to the Digital Terminal Equipment (DTE)
and as a digital line port to the server running Avaya Communication
Manager.
The DLC connects the following EIA 232C equipment to the system:
ethernet
Assigns an Ethernet data module. The Ethernet Data Module screen
assigns the 10BaseT port on the Control-LAN (C-Lan) circuit pack. This
port provides a TCP/IP connection to network hub or LAN. See
Administration for Network Connectivity for Avaya Communication
Manager, 555-233-504, for more information on Ethernet data modules.
ni-bri
Assigns an NI-BRI Data Module.
Printers
Non-Intelligent Data Terminals
Intelligent Terminals, Personal Computers (PCs)
Host Computers
Information Systems Network (ISN), RS-232C Local Area Networks
(LANs), or other data switches.
Data Module
2 of 3
Issue 2.1 May 2006
883