Avaya Communication Manager Administrator's Manual page 1661

Hide thumbs Also See for Communication Manager:
Table of Contents

Advertisement

Note:
The Answer Supervision Timeout field on the Trunk Group screen provides
Note:
timed answer supervision for circuit packs without administrable timers. Since
trunk groups might contain ports on more than one circuit pack, it's possible you
might need to use both timers with the same trunk group. If so, set the Outgoing
End of Dial field and the Answer Supervision Timeout field to the same value.
During a cut-through operation, timing begins after Communication Manager sends each
outgoing digit and ceases when answer supervision is received. If the timer expires,
Communication Manager acts as if it has received answer supervision. On senderized
operation, the timer begins after the switch sends the last digit collected. The timer ceases
when answer supervision is received. If the timer expires, Communication Manager acts as if it
has received answer supervision.
Valid entries
1 to 254 in
increments of 1
Outgoing Glare Guard (msec)
This field only appears for outgoing and two-way trunk groups.
Valid entries
100 to 25500 in
increments of
100
Outgoing Last Digit (sec)
This field is only administrable if the Trunk Type field is dis or cont and the trunk group
Direction field is two-way or outgoing. Only TN497 and TN2140 ports receive this timer.
Valid entries
1 to 40 in
increments of 1
Usage
Enter the maximum time, in seconds, that Communication Manager will
wait to receive answer supervision for outgoing calls on the ports
controlled by firmware timers. For Brazil pulsed E&M signaling, use 40.
Usage
Enter the minimum interval that must elapse between a trunk's release
from an outgoing call and its seizure for another outgoing call. This field
cannot be blank. This delay gives the far-end time to release all
equipment after the outgoing trunk is released.
Usage
Enter the maximum time that Communication Manager will wait for the
next digit dialed. After the timer expires, no more digits are accepted by
the circuit pack.
Trunk Group
Issue 2.1 May 2006
1661