3.3.23 Power Supply/Sensor Board and Contact Assy

(1) Remove the upper cover assy (see 3.3.1).
(2) Remove the lower base unit (see 3.3.5).
(3) Remove the M5B-PCB (See 3.3.21).
(4) Remove the transformer (see 3.3.22).
(5) Remove the AC inlet 1 from the base plate 2.
(6) Remove the screw 3 and remove the grounding (earth) wire 4.
(7) Remove three screws 5, and remove the power supply/sensor board 6 and contact assy 7
together.
(8) Unlock two latches 8, and remove contact assy 7 from the power supply/sensor board 6.
Notes : 1.
2.
3.
Be careful about the sensor (paper supply) when reinstalling the lower base.
Make sure that no excessive force is applied to the power supply switch.
When installing the power supply/sensor onto the base plate, be careful not to bend the
base plate (it is desirable to place a block underneath it to prevent bending).