Dtc 3-5: Short To Ground In Driver's Seat Belt Tensioner - Honda S2000 Service Manual

2000-2003
Hide thumbs Also See for S2000:
Table of Contents

Advertisement

sRs
DTC Troubleshooting (cont'd)
DTC 3-5: Short to Ground in Driver's Seat Belt
Tensioner
Special Tools Required
. SRS inflator simulator 07SAZ-T84011A
. SRS simulator lead C 07TAZ-S25011A
1. Erase the DTC memory (see page 23-19).
2. Turn the ignition switch ON (ll), and check that the
SRS indicator comes on for about 6 seconds and
then goes off.
Does the SRS indicatot stay on?
YES Go to step 3.
NO- Intermittent failure, system is OK at this time.
Go to Troubleshooting Intermittent Failures (see
page 23-19).
3. Turn the ignition switch OFF, then disconnect the
battery negative cable, and wait for 3 minutes.
4. Disconnect the driver's seat belt tensioner 2P
connector from the SRS main harness (A).
Connectthe SRS inflator simulator (2 O conneclor)
and the simulator lead to the SRS main harness.
23-44
6. Reconnectthe battery negative cable.
7. Erase the DTC memory.
8. Read the DTC.
ls DTC 3-5 indicated?
YES- Go to step 9.
NO Short to ground in the drive/s seat belt
tensioner; replace the driver's seat belt (see page
23-4l.a
9. Turn the ignition switch OFF, then disconnect the
battery negative cable, and wait for 3 minutes.

Advertisement