General Configuration Command Set
Configuring Power over Ethernet (PoE)
2.2.5.9

clear inlinepower assigned

Use this command to clear the power value manually assigned to one or more modules.
clear inlinepower assigned [slot-number]
Syntax Description
slot-number
Command Defaults
If slot-number is not specified, power value assignments will be cleared from all
modules.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to clear power assignments to all modules in the chassis:
Matrix(rw)->clear inlinepower assigned
2-106 Matrix DFE-Platinum and Diamond Series Configuration Guide
(Optional) Clears the power assignment from a specific
module.