SNMP Configuration Command Set
Configuring SNMP Target Addresses
Command Defaults
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to configure a trap notification called "TrapSink." This trap notification
will be sent to the workstation 192.168.190.80 (which is target address "tr"). It will use security and
authorization criteria contained in a target parameters entry called "v2cExampleParams". For more
information on configuring a basic SNMP trap, refer to
Matrix(rw)->set snmp targetaddr tr 192.168.190.80 param v2cExampleParams
taglist TrapSink
5-50 Matrix DFE-Platinum and Diamond Series Configuration Guide
If not specified, udpport will be set to 162.
If not specified, mask will be set to 255.255.255.255
If not specified, timeout will be set to 1500.
If not specified, number of retries will be set to 3.
If taglist is not specified, none will be set.