4
Flange sealings and static sealings
The following procedure describes how to fit flange sealings and static sealings.
1
2
3
4
O-rings
The following procedure describes how to fit o-rings.
1
2
Product manual - IRB 7600
3HAC022033-001 Revision: AH
Action
Mount the sealing correctly with a mounting tool.
Never hammer directly on the sealing as this may
result in leakage.
Action
Check the flange surfaces. They must be even and free from pores.
It is easy to check flatness using a gauge on the fastened joint (without sealing com-
pound).
If the flange surfaces are defective, the parts may not be used because leakage could
occur.
Clean the surfaces properly in accordance with the recommendations of ABB.
Distribute the sealing compound evenly over the surface.
Tighten the screws evenly when fastening the flange joint.
Action
Ensure that the correct o-ring size is used.
Check the o-ring for surface defects, burrs,
shape accuracy, or deformation.
© Copyright 2007 - 2023 ABB. All rights reserved.
4.2.3 Mounting instructions for sealings
Note
A
xx2000000072
A Gap
Note
Defective o-rings, including damaged
or deformed o-rings, may not be used.
Continues on next page
4 Repair
Continued
211