Table 68: Chassis Component Alarm Conditions on QFX10000 Modular Models
Chassis
Component
Alarm Condition
Control
A Control board has
board
failed.
A Control board has
been removed.
Line Cards
A line card is offline.
A line card has failed.
A line card has been
removed.
Fan trays
A fan tray has been
removed from the
chassis.
One fan in the chassis is
not spinning or is
spinning below required
speed.
A fan is not receiving
power from the fan tray
controller.
Fan Tray
A fan tray controller has
failed.
Controller
One of the fan tray
controller in the chassis
is not receiving enough
power.
Switch
One of the SIB has failed.
Interface
Boards
(SIBs)
SATA SSD
The SSD has failed or
removed.
slot
Chapter 5: Troubleshooting
Alarm
Severity
Remedy
Major
Replace the failed Control board.
(red)
Minor
Install a Control board in the empty
(yellow)
slot.
Minor
Check the line card. Remove and
(yellow)
reinstall the line card. If this fails,
replace the failed card.
Major
Replace the failed line card.
(red)
Major
Install a line card in the empty slot.
(red)
Major
Install the missing fan tray.
(red)
Major
Replace the fan tray.
(red)
Major
Check and replace the failed fan tray
(red)
controller if required.
Minor
Check and replace the failed fan tray
(yellow)
controller if required.
Major
Check the power supply.
(red)
Minor
Check the below:
(yellow)
The SIB is not receiving power.
The fan tray controller is having a
power problem.
Major
Install the SSD.
(red)
251