QFX10008 Switch Hardware Guide
Table 18: LEDs on an DC Power Supply in QFX10000
LED
or
INP1
INP2
PWR OK
FAULT
62
Figure 26: LEDs on a DC Power Supply in QFX10000 Switches
1—
INP1–Source input 1
2—
INP2–Source input 2
Table 18 on page 62
describes the LEDs in QFX10008 and QFX10016 modular chassis.
Color
State
Yellow
Blinking
Green
Solid
Unlit
Off
Green
Solid
Yellow
Blinking
Red
Solid
Unlit
Off
3—
PWR OK
4—
FAULT
Description
Indicates one of the following:
DC power input voltage is not within normal operating
range.
DC power is within operating range (-40 VDC to -72
VDC).
The power supply is switched off.
DC power output is within normal operating range.
The output is out of the limits.
Power supply has failed and must be replaced.
Power supply is functioning normally. Or, only one input
is powered and the enable switch for the input that is
not powered is set to
. See
ON
to a QFX10000" on page 167
the enable switches.
Copyright © 2019, Juniper Networks, Inc.
"Connecting DC Power
for more information on