Figure 24: Leds On An Ac Power Supply In Qfx10000 Switches; Table 15: Leds On An Ac Power Supply In Qfx10000 - Juniper QFX10008 Hardware Manual

Hide thumbs Also See for QFX10008:
Table of Contents

Advertisement

QFX10008 Switch Hardware Guide

Table 15: LEDs on an AC Power Supply in QFX10000

LED
or
INP1
INP2
PWR OK
FAULT
58

Figure 24: LEDs on an AC Power Supply in QFX10000 Switches

1—
FAULT
2—
PWR OK
Table 15 on page 58
describes the LEDs on an AC power supply in QFX10008 and
QFX10016 modular chassis.
Color
State
Yellow
Blinking
Green
Solid
Dark
Unlit
Green
Solid
Yellow
Blinking
Dark
Unlit
Red
Solid
1
2
3
4
3—
INP2
4—
INP1
Description
Indicates one of the following:
AC power input voltage is not within normal operating
range.
AC is within operating range (200–240 VAC).
The power supply is switched off.
DC power output is within normal operating range.
The output is out of the limits.
Power supply is functioning normally.
Power supply has failed and must be replaced. Or, only
one input is powered and the enable switch for the
input that is not powered is set to
AC Power to a QFX10000" on page 167
information about the enable switches.
–Source input 2
–Source input 1
ON
. See
"Connecting
for more
Copyright © 2019, Juniper Networks, Inc.