Manually Removing a QFX10008 from a 4-Post Rack

Copyright © 2019, Juniper Networks, Inc.

Figure 157: Moving the QFX10008 Using a Mechanical Lift

QFX10000 Clearance Requirements for Airflow and Hardware Maintenance on page 121
If you cannot use a mechanical lift to remove the switch (the preferred method), you can
install it manually.
CAUTION:
The chassis weighs approximately 145 lb (66 kg) with only the
fan tray controllers installed. Lifting the chassis and mounting it in a rack or
cabinet requires at least four people.
Make sure the chassis is empty (contains only the backplane) before you lift
it.
CAUTION:
When removing more than one switch chassis from a rack, remove
the switches in order from top to bottom.
Chapter 4: Maintaining Components
245