Juniper QFX10008 Hardware Manual page 252

Hide thumbs Also See for QFX10008:
Table of Contents

Advertisement

QFX10008 Switch Hardware Guide
252
Table 68: Chassis Component Alarm Conditions on QFX10000 Modular
Models (continued)
Chassis
Component
Alarm Condition
Ethernet
The Ethernet
management interface
on the Control board is
down.
Hot
Too many hot-swap
interrupts are occurring.
swapping
Power
A power supply has been
removed from the
supplies
chassis.
A power supply has a
high temperature.
A power supply input has
failed.
A power supply output
has failed.
A power supply has
failed.
AC and DC power
supplies are installed.
Inadequate number of
power supplies.
Alarm
Severity
Remedy
Minor
Check the interface cable
(yellow)
connection.
Reboot the system.
If the alarm recurs, open a support
case using the Case Manager link at
https://www.juniper.net/support/
or call 1-888-314-5822 (toll free, US
& Canada) or 1-408-745-9500
(from outside the United States).
Major
Replace the failed components.
(red)
Minor
Install a power supply in the empty
(yellow)
slot.
Major
Replace the failed power supply.
(red)
Major
Check power supply input connection
(red)
and the power cord.
Major
Check power supply output
(red)
connection.
Major
Replace the failed power supply.
(red)
Major
Do not mix AC and DC power supplies.
(red)
Major
Install an additional power supply.
(red)