16.2

Repeat Mode

In repeat mode, the input voltage on one selected pin is comparator converted repeatedly. Table 16.3
lists the Repeat Mode Specifications. Figure 16.5 shows Registers ADCON0 and ADCON1 in Repeat
Mode.
Table 16.3
Repeat Mode Specifications
Item
Function
Start conditions
Stop condition
Interrupt request generation
timing
Input pin
Reading of result of
comparator conversion
Rev.1.30
Apr 14, 2006
REJ09B0222-0130
The Input voltage on one pin selected by bits CH2 to CH0, and the
ADGSEL0 bit is comparator converted repeatedly
• When the ADCAP bit is set to 0 (software trigger),
set the ADST bit to 1 (comparator conversion starts).
• When the ADCAP bit is set to 1 (capture),
a timer Z interrupt request is generated while the ADST bit is set to 1.
Set the ADST bit to 0.
Not generated
Selects one of AN8 to AN11.
Read AD register.