R8C/18 Group, R8C/19 Group
15.1.3

Continuous Receive Mode

Continuous receive mode is selected by setting the U0RRM bit in the UCON register to 1 (enables
continuous receive mode). In this mode, reading the U0RB register sets the TI bit in the U0C1
register to 0 (data in the U0TB register). When the U0RRM bit is set to 1, do not write dummy data to
the U0TB register by a program.
Rev.1.30
Apr 14, 2006
REJ09B0222-0130
Page 156 of 233
15. Serial Interface