R8C/18 Group, R8C/19 Group
When the VW2C1 bit is set
to 0 (digital filter enabled).
When the VW2C1 bit is
set to 1 (digital filter
disabled) and the
VW2C7 bit is set to 0
(Vdet2 or above).
When the VW2C1 bit is
set to 1 (digital filter
disabled) and the
VW2C7 bit is set to 1
(Vdet2 or below).
VCA13: Bit in VCA1 register
VW2C1, VW2C2, VW2C6, VW2C7: Bit in VW2C register
Figure 7.9
Operating Example of Voltage Monitor 2 Interrupt and Voltage Monitor 2 Reset
Rev.1.30
Apr 14, 2006
REJ09B0222-0130
VCC
Vdet2
(Typ. 3.30 V)
(1)
2.7 V
1
VCA13 bit
0
Sampling clock of digital filter
× 4 cycles
1
VW2C2 bit
0
Voltage monitor 2
interrupt request
(VW2C6 = 0)
Internal reset signal
(VW2C6 = 1)
1
VW2C2 bit
0
Voltage monitor 2
interrupt request
(VW2C6 = 0)
1
VW2C2 bit
0
Voltage monitor 2
interrupt request
(VW2C6 = 0)
Internal reset signal
(VW2C6 = 1)
The above applies under the following conditions.
• VCA27 bit in VCA2 register = 1 (voltage detection 2 circuit enabled)
• VW2C0 bit in VW2C register = 1 (voltage monitor 2 interrupt and voltage monitor 2 reset enabled)
NOTE:
1. If voltage monitor 1 reset is not used, set the power supply to VCC ≥ 2.7.
Page 50 of 233
7. Voltage Detection Circuit
Sampling clock of digital filter
× 4 cycles
Set to 0 by a program
Set to 0 by interrupt request
acknowledgement
Set to 0 by a program
Set to 0 by interrupt
request acknowledgement
Set to 0 by a program
Set to 0 by interrupt
request
acknowledgement