Page 2
Renesas Electronics. Renesas Electronics shall not be in any way liable for any damages or losses incurred by you or third parties arising from the use of any Renesas Electronics product for an application categorized as “Specific”...
Page 3
R8C 2A/B Washer Platform R8C Series – Flash MCU Microcomputer Development Environment System Page 1 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556 Fax: (86-21) 6888-0559...
Page 4
RSSHEUM0003 - 0101 Rev.1.00 Page 2 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556 Fax: (86-21) 6888-0559 Zip: 200120...
Page 5
Edition Published by: Renesas System Solutions (Beijing) Co., Ltd. Shanghai Branch. Date: March 5, 2008 Version 1.01 Copyright(C): Renesas System Solutions (Beijing) Co., Ltd. Shanghai Branch. All rights reserved. Trademarks a) General All brand or product names used in this manual are trademarks or registered trademarks of their respective companies or organizations.
Page 6
Do not attempt to use the platform board until you fully understand its layout concept. MCU: Throughout this document, the term “Platform” shall be defined as the Renesas R8C 2A/B washer platform, which is for washing machine demo and prototype design reference.
Page 7
No warranty of fitness for a particular purpose is offered. The user assumes the entire risk of using the product. Any liability of Renesas is limited exclusively to the replacement of defective materials or workmanship.
Page 8
2. No license is granted by implication or otherwise under any patents or other rights of any third party or Renesas. 3. MEDICAL APPLICATIONS: Renesas Technology’s products are not authorized for use in MEDICAL APPLICATIONS without the written consent of the appropriate officer of Renesas Technology (Asia Sales company).
Page 9
Please use this user’s manual to understand on how to operate the platform board, which also can help user to be familiar with Renesas R8C series MCU for washing machine application.
3.1 Modes of Operation ........................30 3.1.1 Platform running mode ....................30 Page 8 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556 Fax: (86-21) 6888-0559...
Page 11
5.2 Test AC output with loading..................... 42 5.3 Test unexpected power down recovery function ..............43 Appendix:............................44 Page 9 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556 Fax: (86-21) 6888-0559...
For the AC driving part, All of the triacs used on this platform is Renesas triac products that well match consumer and home appliance electrical characters and requirement, customer can do the testing and evaluation very conveniently with this platform.
11), Serial communication 12), A/D for analog input processing 13), I2C EEPROM communication Page 11 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556 Fax: (86-21) 6888-0559...
1, AC driving output portion, including washer motor driving and valve driving 2, Renesas Triac array, in this platform, especially, all the triacs use Renesas products 3, AC power input port. AC power controller “K1” is not mounted on the board for security consideration because if “K1”...
Renesas MCU R8C 2A/B. Father more, we specially unutilized Renesas Triac as the AC driving output control, which is idea for washer application, we provide them on the platform for customer evaluation and testing.
Below picture shows the available interface provided or reserved for future using on this platform, for detail, please refer to the Notes. Page 14 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
3, Renesas Triac array (BCR8PM-14LE, BCR2PM-14LE, BCR08AM-14A) 4, Function simulation LED (simulate the AC driving output functions) Page 15 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
And in this platform, this Page 16 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
Page 19
“ + ”, “ - ”, “ Cancel ”, and “ OK ” key, for detail key functions, please refer to Part 2: User inter face. Page 17 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
When the program runs to the end, the platform will run to “ Stand By ” mode. Page 18 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
No function Save water Tube dry Save water & Tube dry Page 19 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556 Fax: (86-21) 6888-0559 Zip: 200120...
“ OK ” key, user can select the dedicated function or the available parameters in current menu. Page 20 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
By pressing “ OK ” key, the next level menu will display. 1, First page 2, Second page Page 21 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556 Fax: (86-21) 6888-0559...
“ 0 minutes ” to “ 40 minutes ”. 2.2.3.3 Wash time setting display Page 22 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
Page 25
“ The first time rinse water ”, by pressing “ + ” or “ - ” key user can shift up and down the available save water parameter values as below (cycle over): Page 23 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
Page 26
Page 24 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
No function Save water Tube dry Save water & Tube dry Page 25 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556 Fax: (86-21) 6888-0559 Zip: 200120...
Actually, before the first level menu displayed, there is a cover page menu display, which shows Renesas company information. This page will show on screen for 3 seconds after “ Power ” key pressed in “ Stand By ” mode, then LCD will display the first level menu.
The platform have 7 LEDs for displaying platform board power status and the AC output situation. Below table show the function of each LED: Page 27 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
Page 28 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
20 times (0.5 second on, 0.5 second off) every 15 minutes. All these functions are described in relative part that use buzzer. Page 29 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
Run: The platform is running user set program. Preset: The platform is running in preset mode Page 30 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
While water level does not reach the user setting value in 20 minutes, platform will alarm and start to run error processing program. Page 31 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
(motor cycling time use wash set time subtracting 30 seconds) and then runs 30 seconds balance washing motor cycle. Page 33 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
During unbalance adjusting, the program left time will be increased accordingly. Page 34 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
The platform enabled the power down recovery function using R8C 2A/2B MCU Voltage Detection function. For technical details, please refer to the schematic and s/w source code. Page 36 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
The figure below shows the platform s/w structure and almost all the functions in C source code, and the interrupt routine is also included. Page 38 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
Page 41
RSSHEUM0003 - 0101 Rev.1.00 Page 39 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556 Fax: (86-21) 6888-0559 Zip: 200120...
Page 42
10, The “ cut_off_power ” is used to detect the unexpected power down situation. Page 40 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
Tiny or SLP (Windows98SE/ME/2000/XP) Below picture shows the platform debugging with host PC and Renesas E8 debugger. Please note that, in debugging mode, do not mount “K1” (Relay) onto the board and also do not short Pin 3 and Pin 4 of “K1” on the board, because if Pin 3 and Pin 4 of “K1” shorted, system 5V is floating on 220V AC, which will damage E8 debugger and host PC.
1, AC motor for demo (220V, 90r/min—1250r/min, 15W, 0.16A); 2, AC power input (220V, 50Hz /60Hz); Page 42 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556...
Rev.1.00 Appendix: Below are the platform washing program time tables. Page 44 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556 Fax: (86-21) 6888-0559 Zip: 200120...
Page 47
RSSHEUM0003 - 0101 Rev.1.00 Page 45 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556 Fax: (86-21) 6888-0559 Zip: 200120...
Page 48
RSSHEUM0003 - 0101 Rev.1.00 Page 46 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556 Fax: (86-21) 6888-0559 Zip: 200120...
Page 49
RSSHEUM0003 - 0101 Rev.1.00 Page 47 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556 Fax: (86-21) 6888-0559 Zip: 200120...
Page 50
RSSHEUM0003 - 0101 Rev.1.00 Page 48 Renesas System Solution (Beijing) Co., Ltd, Shanghai Branch Unit 207 AZIA Center, No.1233 Lujiazui Ring Road, Pudong District, Shanghai, China Tel: (86-21) 6888-0556 Fax: (86-21) 6888-0559 Zip: 200120...
Page 51
Please be sure to implement safety measures to guard against the possibility of physical injury, and injury or damage caused by fire in the event of the failure of a Renesas product, such as safety design for hardware and software including but not limited to redundancy, fire control and malfunction prevention, appropriate treatment for aging degradation or any other applicable measures.