150
C
8: T
HAPTER
IMING AND

Assertion Levels

A
C
M
LARM
ONTROLLER
ANAGEMENT
When a fault condition occurs on the fan unit or power supply, a signal is
sent to TAC indicating a fault condition. The signal that the fan unit or
power supply sends may use one of the following assertion levels:
Active-High — Signal indicates the assertion state as a logic ONE state.
Active-Low — Signal indicates the assertion state as a logic ZERO state.
The power supply and fan unit assertion levels are configured for the
following parameters (see Table 8-2). Assertion levels are normally set to
active-low, unless otherwise specified by the auxiliary device vendor. The
default is set to active-low.
Table 8-2 Assertion Level Parameters
Parameter
PS-temp
DC-monitor
AC-monitor
Fan-temp
Fan-rotation
Description
Set to report the temperature of the power
supply.
Set to report DC current faults of the power
supply.
Set to report AC current faults of the power
supply.
Set to report temperature faults of the fan
unit.
Set to report rotation faults of the fan unit.
ADC Telecommunications, Inc.