ADC CUDA 3 Administration Manual page 377

Ip access switch cli-based administration guide
Table of Contents

Advertisement

Cuda 12000 IP Access Switch CLI-based Administration Guide
Sync Interval (millisec)
The Sync Interval parameters sets the time interval between the CMTS
transmission of SYNC messages. By default, the SYNC message is sent by the
MAC hardware every 5 milliseconds. Acceptable values are 1 to 200
milliseconds.
You set the sync interval by performing the following tasks.
Task
1. Enter interface cable mode.
2. Configure the CMTS ranging sync
interval.
UCD-Interval
The UCD (Upstream Channel Descriptor) Interval sets the time interval
between CMTS transmission of Upstream Channel Descriptor for each active
upstream channel. By default, the UCD is sent every 2000 milliseconds.
Acceptable values are 1 to 2000 milliseconds.
Task
1. Enter interface cable mode.
2. Configure the CMTS ranging UCD
interval.
Configuring the MAC Interface
Command
interface cable <c/s/i>
sync-interval <value>
Command
interface cable <c/s/i>
ucd-interval <value>
375

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cuda 12000

Table of Contents