Viewing Fault Reporting Status
A
C
M
LARM
ONTROLLER
ANAGEMENT
Each fault condition displays one of the following states.
disabled — Reporting is not specified for the fault condition. An SNMP
Trap or syslog message is not generated when the fault condition occurs.
faulted — Fault reporting is specified. An SNMP trap or syslog message is
generated when the fault condition occurs.
okay — Fault reporting is specified.
Use the show chassis-fault status command to display the state of each
fault condition.
Example
The following example displays that faults are to be reported for the
backplane power and local power-source-a conditions. In addition, the
display indicates that faults have not occurred for the specified conditions.
cli:192.168.244.212:root# chassis-fault backplane-power
local-pwr-a
cli:192.168.244.212:root# show chassis-fault status
Chassis Fault Status
Bits A Fault
Bits B Fault
Backplane System Fault
Backplane Temp Fault
Backplane Power Fault
Backplane Power A Fault
Backplane Power B Fault
Red Alarm Fault
Blue Alarm Fault
Yellow Alarm Fault
Processor Temp Fault
Ps Temp Fault
Ps AC Fault
Ps DC Fault
Fan Temp Fault
Fan Rotation Fault
Local Pwr A Fault
Local Pwr B Fault
disabled
disabled
disabled
disabled
okay
disabled
disabled
disabled
disabled
disabled
disabled
disabled
disabled
disabled
disabled
disabled
okay
disabled
ADC Telecommunications, Inc.