Configuring Chassis Parameters - ADC CUDA 3 Administration Manual

Ip access switch cli-based administration guide
Table of Contents

Advertisement

78
C
4: C
HAPTER
HASSIS

Configuring Chassis Parameters

C
ONFIGURATION
Chassis configuration includes the following parameters:
Chassis Number — A fixed number assigned to the Cuda 12000 chassis
during manufacturing at the ADC plant.
Chassis ID — User-defined. A unique identification number that you
assign to the Cuda 12000 chassis in the network. The Cuda uses a
multi-range numbering system. Acceptable chassis ID values are 1 to 128,
or the number 255.
Cluster ID — User-defined. An ID of "0" is the default and is
recommended.
Manager — Enables you to force the current primary management
module into a secondary role, thereby forcing the current secondary
management module into the primary role.
Scope — Currently, "Cluster" is the only supported value.
Before you proceed to configure a chassis, you must know the number of
the specific chassis. To display the current chassis configuration, including
the current Chassis Number, use the show chassis-config command within
root mode. For example:
cli:172.16.19.10:root# show chassis-config
Chassis Number:
Chassis Id:
Cluster Id:
Primary Manager Slot:
Secondary Manager Slot: 14
Scope:
cli:172.16.19.10:root#