Configuring Mac Interface Parameters - ADC CUDA 3 Administration Manual

Ip access switch cli-based administration guide
Table of Contents

Advertisement

374
C
18: C
HAPTER
ONFIGURING

Configuring MAC Interface Parameters

C
M
T
ABLE
ODEM
ERMINATION
MAC interface parameters are described in the following sections.
Shared Secret
The Shared Secret parameter is the authentication string shared between the
CMTS and the provisioning server. The shared secret is used by the CMTS to
validate that a cable modem was provisioned by an authorized server. If this
parameter is left blank, the CMTS does not validate a modem's provisioning.
Note that the same value must be configured on the provisioning server.
Configuring no shared secret turns off authentication of modem
provisioning.
Task
1. Enter interface cable mode.
2. Configure the shared-secret for
the current cable interface.
3. Display the shared secret.
Example
cli:172.16.19.10:root# interface 1/1/1
mode: interface:cable:csi(1/1/1)
cli:172.16.19.10:interface:cable:csi(1/1/1)# shared-secret
123456
cli:172.16.19.10:interface:cable:csi(1/1/1)# show shared-secret
Shared Key
ASCII: "4V"
HEX:
"12:34:56"
S
YSTEMS
Command
interface cable <c/s/i>
shared-secret [ascii] <secret-string>
show interface cable <c/s/i>
shared-secret
or
Within cable interface mode:
show shared-secret
ADC Telecommunications, Inc.