Configuring Pos Alarm Reporting - ADC CUDA 3 Administration Manual

Ip access switch cli-based administration guide
Table of Contents

Advertisement

Configuring POS Alarm Reporting

Alarm Report
Line Alarm Indication
Signal (LAIS)
Line Remote Defect
Indication (LRDI)
Path Alarm Indication
Signal (PAIS)
Path Loss of Pointer
(PLOP)
Path Remote Defect
Indication (PRDI)
B2 Signal Degrade (SD) Disabled by default, configures the
Cuda 12000 IP Access Switch CLI-based Administration Guide
You can configure reporting of 12 different POS alarms. To do so, perform
the following tasks within interface pos <c/s/i> mode:
Description
Disabled by default, configures the
interface to report line alarm indication
signal errors.
Disabled by default, configures the
interface to report line remote defect
indication errors.
Disabled by default, configures the
system to report path alarm indication
signal errors. Line terminating
equipment (LTE) send packet alarm
indication signals to alert downstream
path terminating equipment (PTE) of
defects on their incoming line signal.
Enabled by default, configures the
interface to report path loss of pointer
errors. A PLOP error may result from an
invalid pointer or too many new data
flag enabled indications.
Disabled by default, configures the
interface to report path remote defect
indication errors.
interface to report when the B2 signal
degrades enough to meet or cross a
specified Bit Error Rate (BER) threshold.
The default BER threshold for B2 signal
failure is 10-6.
Configuring and Viewing SONET Alarms
Command
To enable reporting:
pos report lais
To disable reporting:
no pos report lais
To enable reporting:
pos report lrdi
To disable reporting:
no pos report lrdi
To enable reporting:
pos report pais
To disable reporting:
no pos report pais
To enable reporting:
pos report plop
To disable reporting:
no pos report plop
To enable reporting:
pos report prdi
To disable reporting:
no pos report prdi
To enable reporting:
pos report sd-ber
To disable reporting:
no pos report sd-ber
To set the B2 Signal Degrade
threshold:
pos threshold sd-ber <number>
133

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cuda 12000

Table of Contents