192
C
9: S
HAPTER
IMPLE
N
M
P
ETWORK
ANAGEMENT
ROTOCOL
Parameter
docs-init-rsp-fail
Provisioning events:
duplicate-addr
isp-addr-high
isp-addr-low
ldap-failed
ldap-restored
prov-service
subnet-addr-high
subnet-addr-low
Routing events:
ospf-nbr-state
(SNMP)
Description
A registration response failure from
the cable modem occurred during the
cable modem initialization process and
was detected on the CMTS side.
Provisioning events refer to faults that
pertain to the FastFlow BPM running
on the Cuda 12000.
A duplicate IP address has been
detected.
The free IP address count exceeded
the upper threshold for the specified
ISP.
The free address count fell below the
lower threshold for the specified ISP.
A directory server access failure
occurred.
Directory server access is operational
after a failure.
A FastFlow BPM service started,
stopped, or failed.
The free IP address count exceeded
the high available address threshold
for a subnet.
The free IP address count fell below
the low available address threshold for
a subnet.
Routing events refer to events that
indicate a change in the state of OSPF
neighbors and OSPF virtual neighbors.
Signifies a change in the state of an
OSPF neighbor on a physical interface.
To send this notification type, note
that you also have to enable sending
of OSPF neighbor state traps using the
report command.