ADC CUDA 3 Administration Manual page 160

Ip access switch cli-based administration guide
Table of Contents

Advertisement

158
C
8: T
HAPTER
IMING AND
A
C
M
LARM
ONTROLLER
ANAGEMENT
You Can Configure This
Signal:
Power Alarm
Temp Fault
Power Fault
PowerA Fail
PowerB Fail
Clock
To configure the alarm signals for transmit over the DB-15 connector and the
associated signals that can trigger them, perform the following tasks. By
default, all faults are configured to not send out their associated alarm
signals over the DB-15 connector:
To Provide Notification of These Faults:
local-pwr-a-fault
local-pwr-b-fault
backplane-pwr-fault
backplane-pwr-a-fault
backplane-pwr-b-fault
ps-ac-fault
ps-dc-fault
processor-temp-fault
ps-temp-fault
fan-temp-fault
local-pwr-a-fault
local-pwr-b-fault
backplane-pwr-a-fault
backplane-pwr-b-fault
ps-ac-fault
ps-dc-fault
local-pwr-a-fault
local-pwr-b-fault
bits-a-fault
bits-b-fault
red-alarm-fault
ADC Telecommunications, Inc.