Data Strobe Timing (DST) Tests

tDSH, DQS Falling Edge Hold Time from CK - Test Method of Implementation

The purpose of this test is to verify that the time interval from the falling edge of the data strobe
output access time to the hold time of the clock, must be within the conformance limit as specified in
the JEDEC Standard JESD79E.

Signals of Interest

Based on the test definition (Write cycle only):
Signals required to perform the test on the oscilloscope:
Optional signal required to separate the signals for the different Ranks:

Test Definition Notes from the Specification

Table 43
Electrical Characteristics and AC Timing
AC Characteristics Parameter
DQS falling edge hold time from CK
AC Characteristics Parameter
DQS falling edge hold time from CK

PASS Condition

The measured time interval between the falling edge of the data strobe hold time from the
associated clock crossing edge should be within the specification limit.

Measurement Algorithm

1
2
3
4
5
6
106
Data Strobe Signal (DQS as Pin Under Test Signal)
Clock Signal (CK as Reference Signal)
Data Strobe Signal (DQS as Pin Under Test Signal)
Data Signal (DQ as Supporting Signal)
Clock Signal (CK as Reference Signal)
Chip Select Signal (CS as additional signal, which requires an additional channel)
Obtain the parameters and settings from the Configuration page.
Pre-condition the scope settings. Verify the actual DUT speed against the user speed selection at
the Setup page.
Perform signal checking on all the signals in-use in the measurement to ensure that it can be
triggered during the test. This includes Vp-p, Vmin, Vmax and Vmid of each signal.
Perform signal skew checking on the DQ-DQS to ensure that it can be triggered during the
Read/Write separation later.
Chip Select (CS) option is only applicable if the user has selected "Yes" for the Verify Selected
Rank Only option in the Configuration page. It uses the CS-DQS for signal separation. Else, by
default, the DQS-DQ is used for signal separation.
Use the InfiniiScan feature with the Setup time and Hold time to find and capture the Read cycle.
Symbol
DDR 333
Min
Max
Min
tDSH
0.2
0.2
Symbol
DDR 400A
(2.5-3-3)
Min
Max
Min
tDSH
0.2
0.2
DDR1 Compliance Testing Methods of Implementation
DDR 266
DDR 200
Max
Min
Max
0.2
DDR 400B
DDR 400C
(3-3-3)
(3-4-4)
Max
Min
Max
0.2
Units
Notes
tCK
Units
Notes
tCK