  • Page 1 Keysight Extended Power Range and Bias Tees Upgrade Kit To Upgrade PNA-X N5247A Option 400 to Option 419 Upgrade Kit Order Number: N5247AU-926 Keysight Kit Number: N5247-60103 Installation Note...
  • Page 3: Warranty Statement

    SHALL NOT BE LIABLE FOR ERRORS OR FOR INCIDENTAL OR CONSEQUENTIAL DAMAGES IN CONNECTION WITH THE FURNISHING, USE, OR PERFORMANCE OF THIS DOCUMENT OR ANY INFORMATION CONTAINED HEREIN. SHOULD KEYSIGHT AND THE USER HAVE A SEPARATE WRITTEN AGREEMENT WITH WARRANTY TERMS COVERING THE MATERIAL IN THIS DOCUMENT THAT CONFLICT WITH THESE TERMS, THE WARRANTY TERMS IN THE SEPARATE AGREEMENT WILL CONTROL.
  • Page 4: Contacting Keysight

    If You Have Problems With the Upgrade Kit Contents Keysight stands behind the quality of the upgrade kit contents. If you have problems with any item in the kit, email Keysight Component Test Division (CTD) Support at support_ctd-soco@keysight.com, or telephone the CTD Hotline at (707) 577-6802 and leave a voice mail message.
  • Page 5: Getting Prepared

    The enclosed Option Entitlement Certificate is a receipt, verifying that you have purchased a NOTE licensed option for the PNA of your choice. You must now use a Keysight Web page to request a license key for the instrument that will receive the option.
  • Page 6 Downloading the Online PNA Service Guide To view the online Service Guide for your PNA model number, use the following steps: 1. Go to www.keysight.com. 2. In the Search box, enter the model number of the analyzer (Ex: N5242A) and click Search.
  • Page 7: Tools Required For The Installation

    Products affected ........N5247A Option 400 Installation to be performed by ......Keysight service center or personnel qualified by Keysight Estimated installation time .
  • Page 8 Items Included in the Upgrade Kit Check the contents of your kit against the following list. If any part is missing or damaged, contact Keysight Technologies. Refer to “Getting Assistance from Keysight” on page Table 1 Contents of Upgrade Kit N5247-60103...
  • Page 9 Table 1 Contents of Upgrade Kit N5247-60103 Description Part Number Desig. W101 RF cable, A29 port 1 reference coupler to A38 port 1 source attenuator N5247-20083 W102 RF cable, A38 port 1 source attenuator to front-panel port 1 SOURCE OUT...
  • Page 10 Table 1 Contents of Upgrade Kit N5247-60103 Description Part Number Desig. Ribbon cable, A23 test set motherboard J549 to A38 test port 1 source attenuator Ribbon cable, A23 test set motherboard J547 to A39 test port 3 source attenuator N5245-60006...
  • Page 11: Overview Of The Installation Procedure

    Installation Procedure for the Upgrade The network analyzer must be in proper working condition prior to installing this option. Any necessary repairs must be made before proceeding with this installation. This installation requires the removal of the analyzer’s protective outer covers. The analyzer WARNING must be powered down and disconnected from the mains supply before performing this procedure.
  • Page 12 If the model number, serial number, or option number do not match those on your license key, you will not be able to install the option. If this is the case, contact Keysight for assistance before beginning the installation of this upgrade.
  • Page 13 Step 5. Remove Some Bottom-Side (Test Set) Cables Be careful not to damage the center pins of the semirigid cables. Some flexing of the cables may NOTE be necessary but do not over-bend them. Leave the gray flexible cables, the wire harnesses, and the ribbon cables connected where NOTE possible.
  • Page 14 • W50 (N5247-20054) Port 2 RCVR B IN to A27 mixer brick (B) • W56 (N5247-20055) REF 2 RCVR R2 IN to A27 mixer brick (R2) These cables must be saved - they will be reinstalled. • W16 (N5247-20060) A61 port 3 70 GHZ doubler to W15 •...
  • Page 15 Step 6. Remove Port 1 and Port 2 Coupler Assemblies from the Test Set Deck For instructions on removing the coupler assemblies, click the Chapter 7 bookmark “Removing and Replacing the A29-A32 Reference Couplers and Reference Coupler Mounting Brackets” in the PDF Service Guide .
  • Page 16 Step 9. Install the Step Attenuators Refer to Figure 2 for this step of the procedure. New parts are listed in Table 1 on page 7. Use a T-10 TORX driver to tighten all screws. Figure 2 Port 2 and Port 3 Step Attenuators Installation Installation Note N5247-90103...
  • Page 17 Step 10. Reinstall the Port 2 and Port 3 Coupler Assemblies Refer to Figure 3 for this step of the procedure. Use a T-10 TORX driver to tighten all screws. Figure 3 Port 2 and Port 3 Coupler Assemblies Reinstallation Step 11.
  • Page 18 Step 13. Assemble the Port 1 and Port 4 Step Attenuators Refer to Figure 4 for this step of the procedure. New parts are listed in Table 1 on page 7. Use a T-10 TORX driver to tighten all screws. Figure 4 Port 1 and Port 4 Step Attenuators Assembly Installation Note N5247-90103...
  • Page 19 Step 14. Install the Step Attenuators Refer to Figure 5 for this step of the procedure. New parts are listed in Table 1 on page 7. Use a T-10 TORX driver to tighten all screws. Figure 5 Port 1 and Port 4 Step Attenuators Installation Installation Note N5247-90103...
  • Page 20 Step 15. Reinstall the Port 3 and Port 4 Coupler Assemblies Refer to Figure 6 for this step of the procedure. Use a T-10 TORX driver to tighten all screws. Figure 6 Port 3 and Port 4 Coupler Assemblies Reinstallation Installation Note N5247-90103...
  • Page 21 Step 16. Assemble the Bias Tees Refer to Figure 7 for this step of the procedure. New parts are listed in Table 1 on page Figure 7 Bias Tee Assembly Installation Note N5247-90103...
  • Page 22 Step 17. Install the Bias Tee Assemblies Refer to Figure 8 for this step of the procedure. New parts are listed in Table 1 on page Figure 8 Bias Tee Installation Installation Note N5247-90103...
  • Page 23 Step 18. Install Some Bottom-Side (Test Set) Cables Follow instructions carefully when making cable connections, especially wire harness CAUTION connections. Incorrect connections can destroy components, resulting in additional customer costs. Be careful not to damage the center pins of the semirigid cables. Some flexing of the cables may CAUTION be necessary but do not over-bend them.
  • Page 24 • W146 (N5247-20058) A32 port 2 ref coupler to front-panel REF 2 SOURCE OUT * As shown in Figure 9, install three clamps, part number 1400-1334, to secure W146. Figure 9 Location of Cable Clamps to Secure W146 (N5247-20058) • W124 (N5247-20046) A49 port 2 receiver attenuator to A27 mixer brick (B) Installation Note N5247-90103...
  • Page 25 • W145 (N5245-20066) REF 2 RCVR R2 IN to A27 mixer brick (R2) * As shown in Figure 10, install one clamp, part number 1400-1334, to secure W145 (N5245-20066). Figure 10 Location of Cable Clamp to Secure W145 (N5247-20066) • W116 (N5247-20080) A45 port 2 bias tee to A36 port 2 coupler •...
  • Page 26 • W41 (N5247-20069) A31 port 4 reference coupler to front-panel REF 4 SOURCE OUT • W55 (reuse) (N5247-20067) REF 4 RCVR R4 IN to 3 dB pad on A28 mixer brick (R4) * As shown in Figure 11, install one clamp, part number 1400-1334, to secure W41 (N5247-20069), and install one cable tie, part number 1400-0249, to secure W55 (N5247-20067).
  • Page 27 • W37 (N5247-20070) A30 port 3 reference coupler to front-panel REF 3 SOURCE OUT * As shown in Figure 12, install one clamp, part number 1400-1334, to secure W37 (N5247-20070). Figure 12 Location of Cable Clamp to Secure W37 (N5247-20070) •...
  • Page 28 • W120 (N5247-20064) A47 port 3 receiver attenuator to A28 mixer brick (C) • W54 (reuse) (N5247-20062) REF 3 RCVR R3 IN to A28 mixer brick (R3) * As shown in Figure 13, install 2 cable ties, part number 1400-0249, to secure W120 (N5247-20064) and W54 (N5247-20062).
  • Page 29 • W144 (N5247-20071) A29 port 1 reference coupler to A37 reference mixer switch * As shown in Figure 14, install 2 cable ties, part number 1400-0249, to secure W144 (N5247-20071). Figure 14 Location of Cable Ties to Secure W144 (N5247-20071) •...
  • Page 30 • W62 (reuse) (N5247-20111)Port 4 CPLR THRU to A44 port 4 bias tee Install the Ribbon Cables and Wire Harnesses Follow instructions carefully when making cable connections, especially wire harness CAUTION connections. Incorrect connections can destroy components, resulting in additional customer costs.
  • Page 31 Step 19. Install the Braces Refer to Figure 15 for this step of the procedure. New parts are listed in Table 1 on page Figure 15 Brace Installation Step 20. Reinstall Front Panel Assembly For instructions on reinstalling the front panel assembly, click the Chapter 7 bookmark “Removing and Replacing the Front Panel Assembly”...
  • Page 32 4. Using the keyboard, enter the license key in the box provided. The license key is printed on the the license message you received from Keysight. Enter this key exactly as it is printed on the message. 5. Click Enable.
  • Page 33 Perform the Operator’s Check to check the basic functionality of the analyzer. For instructions, click the Chapter 3 bookmark “Tests and Adjustments” in the PDF Service Guide If you experience difficulty with the basic functioning of the analyzer, contact Keysight. Refer to “Contacting Keysight”...