ACQuire Subsystem
ACQuire:CCDF:DURation <numeric_value>
This command sets the CCDF trigger duration.
Syntax
Parameter
Item
Description/Defaul t
numeric_value
A numeric value in second for the CCDF trigger duration:
– Default value: 10 ms
– Minimum value: 100 ns
– Maximum value: 1 s
The value specified will be truncated to a multiple of 10 ns.
The range of values above is determined by CCDF trigger duration × CCDF
frame and must be ≤ 100 s.
Example
ACQ:CCDF:DUR 0.01
90
ACQ
:CCDF
Space
:DUR
This command sets the CCDF trigger duration to
0.01 s.
Keysight 8990B Programming Guide
numeric_value
?
Range of values
100 ns to 1 s