Output Terminals; Control Circuit Output Terminals - YASKAWA V1000 Series Installation & Start-Up Manual

Compact vector control drive
Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

Type
No.
Terminal Name (Function)
Multi-function pulse train input (frequency
RP
reference)
+V
Analog input power supply
Main
Frequency
Multi-function analog input (frequency
A1
Reference
reference)
Input
Multi-function analog input (frequency
A2
reference)
AC
Frequency reference common

Output Terminals

Type
No.
MA N.O. (fault)
Multi-Function
MB N.C. output (fault)
Digital Output
MC Digital output common
P1
Multi-Function
Photocoupler
P2
Output
PC
MP Pulse train output (input frequency)
Monitor Output
AM Analog monitor output
AC Monitor common
Connect a suppression diode as shown in
relay coil. Ensure the diode rating is greater than the circuit voltage.
YASKAWA ELECTRIC TOEP C710606 09B YASKAWA AC Drive V1000 Installation & Start-Up Manual
Table 3.7 Control Circuit Output Terminals
Terminal Name (Function)
Photocoupler output 1 (during run)
Photocoupler output 2 (Frequency agree)
Photocoupler output common
Figure 3.19
3.7 Control Circuit Wiring
Function (Signal Level) Default Setting
Response frequency: 0.5 to 32 kHz
(Duty Cycle: 30 to 70%)
(High level voltage: 3.5 to 13.2 Vdc)
(Low level voltage: 0.0 to 0.8 Vdc)
(input impedance: 3 kΩ)
+10.5 Vdc (max allowable current 20 mA)
Input voltage 0 to +10 Vdc (20 kΩ) resolution
1/1000
Input voltage or input current (Selected by DIP
switch S1) 0 to +10 Vdc (20 kΩ),
Resolution: 1/1000
4 to 20 mA (250 Ω) or 0 to 20 mA (250 Ω),
Resolution: 1/500
0 Vdc
Function (Signal Level)
Default Setting
Digital output
30 Vdc, 10 mA to 1 A; 250 Vac, 10 mA to 1 A
Minimum load: 5 Vdc, 10 mA (reference
value)
Photocoupler output 48 Vdc, 2 to 50 mA
32 kHz (max)
0 to 10 Vdc (2 mA or less) Resolution: 1/1000
0 V
when driving a reactive load such as a
3
73

Hide quick links:

Advertisement

Table of Contents
loading