H3: Analog Inputs; H3 Multi-Function Analog Input Settings - YASKAWA V1000 Series Installation & Start-Up Manual

Compact vector control drive
Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

B.2 Parameter Table
No.
Name
Terminal A1 Signal
H3-01
Level Selection
Terminal A1 Function
H3-02
Selection
H3-03
Terminal A1 Gain
Setting
<22>
H3-04
Terminal A1 Bias
Setting
<22>
Terminal A2 Signal
H3-09
Level Selection
Terminal A2 Function
H3-10
Selection
H3-11
Terminal A2 Gain
Setting
<22>
H3-12
Terminal A2 Input
Bias
<22>
Analog Input Filter
H3-13
Time Constant
<22> Parameter can be changed during run.
<40> The availability of certain parameters depends on the control method used.
H3-
Function
Setting
0
Frequency Bias
344
Use H3 parameters to set the multi-function analog input terminals.
Sets the input level for terminal A1.
0: 0 to +10 V (lower limit)
1: 0 to +10 V (no lower limit)
Sets the function of terminal A1. When
terminal A1 is not used or is used as a through
terminal, this parameter must be set to "F".
Sets the level of the input value selected in
H3-02 when 10V is input at terminal A1.
Sets the level of the input value selected in
H3-02 when 0V is input at terminal A1.
Sets the input signal level for terminal A2.
0: 0 to +10 V (with lower limit)
1: 0 to +10 V (no lower limit)
2: 4 to 20 mA
3: 0 to 20 mA
Sets the function of terminal A2. When
terminal A2 is not used or is used as a through
terminal, this parameter must be set to "F".
Sets the level of the input value selected in
H3-10 when 10 V (20 mA) is input at terminal
A2.
Sets the level of the input value selected in
H3-10 when 0 V (0 or 4 mA) is input at
terminal A2.
Sets the primary delay filter time constant for
terminals A1 and A2. Used for noise filtering.

H3 Multi-Function Analog Input Settings

Max output frequency (E1-04).Same value can be set
using H3-02 and H3-10.
YASKAWA ELECTRIC TOEP C710606 09B YASKAWA AC Drive V1000 Installation & Start-Up Manual
Description

H3: Analog Inputs

Maximum Input Level Possible
Control
Mode
Range Def.
O
V/
P
L
f
M
V
0, 1
0
A A A 410
0 to 31
0
A A A 434
<40>
-999.9 to
100.
A A A
999.9
0%
-999.9 to
0.0
A A A 412
999.9
%
0 to 3
2
A A A 417
Switch between current or voltage
inputs by using DIP switch S1-2
switch on the terminal board.
to I/O Connections on page
0 to 31
0
A A A 418
<40>
-999.9 to
100.
A A A 419
1000.0
0%
-999.9 to
0.0
A A A 41A
999.-
%
0.00 to
0.0
A A A 41B
2.00
3 s
Control
Mode
V/
f
O O O —
Addr.
Pg.
Hex
411
Refer
78.
Pg.
O
P
LV
M