Password Settings: A1-04, A1-05; Copy Function (Optional); Drive Wizard - YASKAWA V1000 Series Installation & Start-Up Manual

Compact vector control drive
Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

Parameter
No.
Name
Parameters selected by the user are stored to the User Parameter menu.
This includes recently viewed parameters or parameters specifically
selected for quick access.
A2-01
Preferred
If parameter A2-33 is set to 1, recently viewed parameters will be
to
Parameters
listed between A2-17 and A2-32. Parameters A2-01 through A2-16
A2-32
1 to 32
must be manually selected by the user.
If A2-33 is set to 0, then recently viewed parameters will not be saved
to the User Parameter group. The entire A2 parameter group is now
available for manual programming.
0: Parameters A2-01 through A2-32 are reserved for the user to create
Preferred
a list of User Parameters.
Parameter
1: Save history of recently viewed parameters. Recently edited
A2-33
Automatic
parameters will be saved to A2-17 through A2-32 for quick access.
Selection
The most recently changed parameter is registered in A2-17. The
second most recently changed parameter is registered in A2-18.

Password Settings: A1-04, A1-05

The user can set a password to the drive to restrict access. The password is selected via
parameter A1-05. The selected password must be entered in parameter A1-04 to unlock
parameter access (i.e., parameter setting A1-04 must match the value programmed into A1-
05). The following parameters cannot be viewed or edited until the value programmed into
A1-04 correctly matches the value as programmed in parameter A1-05: A1-01, A1-02, A1-
03, A1-06 and A2-01 through A2-33.
Note: Parameter A1-05 is hidden from view. To display A1-05, access parameter A1-04 and
simultaneously depress the

Copy Function (Optional)

Using an option, the parameter setting can be copied to another drive. Storing the modified
contents can make restoration easy since the parameters do not have to be set from the
beginning if the drive breaks down and must be replaced. For this drive, the following two
options can be used:
• Copy unit with USB (USB converter with copy function)
• Drive Wizard (Parameter management tool of PC application software)
Copy Unit with USB
Connect and exclusive-use cable to the communication connector on the drive and use the
ON/OFF switch on the copy unit with USB to copy the data

Drive Wizard

Use Drive Wizard to copy the parameter setting to another drive. For details, refer to Help in
the Drive Wizard software.
YASKAWA ELECTRIC TOEP C710606 09B YASKAWA AC Drive V1000 Installation & Start-Up Manual
Description
key and the
key.
4.7 Test Run
Setting
Default
Range
b1-01 to
o2-08
0,1
1
4
165

Hide quick links:

Advertisement

Table of Contents
loading