H2-
Function
Setting
Torque Detection 2
19
(N.C.)
1A
Reverse Direction
1B
Baseblock 2
1C
Motor 2 Selection
1E
Restart Enabled
1F
Overload Alarm OL1
20
OH Pre alarm
Mechanical Weakening
22
(N.O.)
30
During Torque Limit
During Frequency
37
Output
38
Drive Enable
Watt Hour Pulse
39
Output
3C
Drive Mode
3D
Speed Search
3E
PID Feedback Loss
3F
PID Feedback Fault
4A
KEB Operation
4B
Short-Circuit Brake
4C
During Fast-stop
OH Pre-alarm Time
4D
Limit
H2 Parameter
100 to
Functions Reversed
14D
Output Switching of 0
to 92
YASKAWA ELECTRIC TOEP C710606 09B YASKAWA AC Drive V1000 Installation & Start-Up Manual
H2 Multi-Function Digital Output Settings
Open: Output current/torque exceeds the value set in parameter
L6-05 for more time than is set in parameter L6-06.
Closed: Drive is running in the reverse direction.
Open: Drive is in base block condition. Output is disabled.
Closed: Motor 2 is selected by a digital input (H1-
Closed: An automatic restart is performed
Closed: OL1 is at 90% of its trip point or greater.
Closed: Heatsink temperature exceeds the parameter L8-02 value. O O O —
Closed: Mechanical Weakening detected.
Closed: When the torque limit has been reached.
Closed: Frequency is output
Open: Operation stopped, Baseblock, DC Injection Braking, or
Initial Excitation is being performed.
Closed: Multi-function input closes (H1-
Output units are determined by H2-06, outputs 200 ms pulse for
each incremented kWh count.
Closed: Local
Open: Remote(this signal combines setting values 9 and A).
Closed: Speed search is being executed.
Closed: PID Feedback Loss.
PID feedback value is below the level set to b5-13 for longer than
the time set in b5-14.
Closed: PID Feedback Fault.PID feedback value exceeds the level
set to b5-36 for longer than the time set to b5-37.
Closed: KEB is being performed.
Closed: Short-Circuit Braking is active.
Closed: Fast-stop command is entered
Closed: OH Pre-alarm time limit is passed.
Reverse the output switching of the multi-function output
functions. Set the last two digits of 1
signal of that specific function.Examples:
Setting "108" reverses the output of "During baseblock," which is
setting value 08.
Setting "14A" reverses the output of "During KEB operation",
which is setting "4A".
B.2 Parameter Table
Description
= 6A)
to reverse the output
Control
Mode
Pg.
O
V/
P
L
f
M
V
O O O —
O O O —
O O O —
O O − —
= 16)
O O O —
O O O —
O O O —
− O − —
O O O —
O O O —
O O O —
O O O —
O O O —
O O O —
O O O —
O O O —
− − O —
O O O —
O O O —
O O O —
343