U4: Maintenance Monitors - YASKAWA V1000 Series Installation & Start-Up Manual

Compact vector control drive
Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

No.
Name
Cumulative Operation
U3-18
Time at 8th Most
Recent Fault
Cumulative Operation
U3-19
Time at 9th Most
Recent Fault
Cumulative Operation
U3-20
Time at 10th Most
Recent Fault
Accumulated
U4-01
Operation Time
Number of Run
U4-02
Commands
Cooling Fan
U4-03
Operation Time
Capacitor
U4-05
Maintenance
U4-07 IGBT Maintenance
YASKAWA ELECTRIC TOEP C710606 09B YASKAWA AC Drive V1000 Installation & Start-Up Manual
Description
Displays the cumulative operation time at the
eighth most recent fault.
Displays the cumulative operation time at the
ninth most recent fault.
Displays the cumulative operation time at the
tenth most recent fault.

U4: Maintenance Monitors

Use U4 parameters to display drive maintenance information.
Displays the cumulative operation time of the
drive. The value for the cumulative operation
time counter can be set in parameter o4-01.
Use parameter o4-02 to determine if the
operation time should start as soon as the
power is switched on or only while the run
command is present. The maximum number
displayed is 99999, after which the value is
reset to 0.
Displays the number of times the run
command is entered. Reset the number of run
commands using parameter o4-13. This value
will reset to 0 and start counting again after
reaching 65535.
Displays the cumulative operation time of the
cooling fan. The default value for the fan
operation time is set to parameter o4-03. This
value will reset to 0 and start counting again
after reaching 65535.
Displays main circuit capacitor usage time in
in percent of their expected performance life.
Parameter o4-06 resets this monitor.
Displays IGBT usage time as a percent of
expected performance life. One of the multi-
function contact outputs can be set to close
when the value reaches 50% (H2-
triggering an alarm. One of the multi-
function contact outputs can be set to close
when the value reaches 90% (H2-
triggering an alarm. Parameter o4-09 resets
this monitor.
B.2 Parameter Table
Analog
Output
Unit
Level
No signal
output
1 h A A A 811E
available
No signal
output
1 h A A A 812
available
No signal
output
1 h A A A 813
available
No signal
1 h A A A
output avail.
No signal
output avail.
No signal
1H A A A
output avail.
No signal
1% A A A
output avail.
= 2F),
No signal
1% A A A 7D7
output avail.
= 10),
Control
Mode
Addr.
O
V/
P
Hex
L
f
M
V
4C
A A A
76
67
B
7C
379