LED Operator Display
Cause
LED Operator Display
Cause
The following simultaneous contradictory settings:
C6-05 is greater than 6 and C6-04 is greater than C6-03
(carrier frequency lower limit is greater than the upper
limit). If C6-05 is less than or equal to 6, the drive
operates at C6-03.
Upper and lower limits between C6-02 and C6-05
contradict each other.
Cause
Scaling for the Pulse Train
monitor is set to 0 (H6-07 =
0) while H6-06 is not set to
101, 102, 105, or 116.
YASKAWA ELECTRIC TOEP C710606 09B YASKAWA AC Drive V1000 Installation & Start-Up Manual
oPE11
oPE13
5.6 Operator Programming Errors
Error Name
Possible Solutions
Correct the settings for E1-04, -06, -07 and -09 (or E-04,
-06, -07, -09 for motor 2).
Error Name
Carrier Frequency Setting Error
Correct the setting for the carrier frequency.
Possible Solutions
Correct the parameter settings.

Pulse Monitor Selection Error

Incorrect setting of monitor selection for Pulse Train
(H6-06) .
Possible Solutions
Change scaling for the Pulse Train monitor or set H6-06
to 101, 102, 105, or 116..