Tuning; Acceleration And Deceleration Times - YASKAWA V1000 Series Installation & Start-Up Manual

Compact vector control drive
Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

B.2 Parameter Table
<12> Default setting value is dependent on parameter o2-04, Drive/kVA Selection.
<14> Default setting value is dependent on parameter o2-09, Initialization Spec. Selection.
<22> Parameter can be changed during run.
<32> A coasting motor may require a braking resistor circuit to bring the motor to a stop in the required time.
<33> Increase the setting value in increments of 0.1 when estimating the minimum output frequency for a motor
coasting at high speed while attempting Speed-Estimation Type Speed Search.
<34> Increase this value if an OV overvoltage fault occurs when performing Speed Search at start.
<57> Default setting value is dependent on parameter o2-04, Drive/kVA Selection and C6-01, Drive Duty Selection.
C: Tuning
C parameters are used to adjust the acceleration and deceleration times, S-curves, slip- and
torque compensation functions and carrier frequency selections.
No.
Name
C1-01
Acceleration Time 1
<22>
C1-02
Deceleration Time 1
<22>
C1-03
Acceleration Time 2
<22>
C1-04
Deceleration Time 2
<22>
Acceleration Time 3
C1-05
(Motor 2 Accel
<22>
Time 1)
Deceleration Time 3
C1-06
(Motor 2 Decel
<22>
Time 1)
Acceleration Time 4
C1-07
(Motor 2 Accel
<22>
Time 2)
Deceleration Time 4
C1-08
(Motor 2 Decel
Time 2)
316
C1: Acceleration and Deceleration Times
Use C1 parameters to configure motor acceleration and deceleration.
Sets the time to accelerate from 0 to
maximum frequency.
Sets the time to decelerate from maximum
frequency to 0.
Sets the time to accelerate from 0 to
maximum frequency when Accel/Decel
times 2 are selected by a digital input.
Sets the time to decelerate from maximum
frequency to 0 when Accel/Decel times 2 are
selected by a digital input.
Sets the time to accelerate from 0 to
maximum frequency when Accel/Decel
times 3 are selected by a digital input.
Sets the time to decelerate from maximum
frequency to 0 when Accel/Decel times 3 are
selected by a digital input.
Sets the time to accelerate from 0 to
maximum frequency when Accel/Decel
times 4 are selected by a digital input.
Sets the time to decelerate from maximum
frequency to 0 when Accel/Decel times 4 are
selected by a digital input.
YASKAWA ELECTRIC TOEP C710606 09B YASKAWA AC Drive V1000 Installation & Start-Up Manual
Description
Control
Mode
Range Def.
O
V/
P
L
f
M
V
0.0 to
6000.0
10.0 s S S S
<6>
0.0 to
6000.0
10.0 s S S S
<6>
0.0 to
6000.0
10.0 s A A A 202
<6>
0.0 to
6000.0
10.0 s A A A 203
<6>
0.0 to
6000.0
10.0 s A A A 204
<6>
0.0 to
6000.0
10.0 s A A A 205
<6>
0.0 to
6000.0
10.0 s A A A 206
<6>
0.0 to
6000.0
10.0 s A A A 207
<6>
Addr.
Pg.
Hex
200
132
201
132

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents