Drive Input Voltage Setting: E1-01; Input Voltage Setting Value: E1-01 - YASKAWA V1000 Series Installation & Start-Up Manual

Compact vector control drive
Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

4.6 Basic Drive Setup Adjustments
Single-Phase 200 V
Carrier
Model
Frequency
(Capacity)
(kHz)
2
BA0018*
8
- / 3.7 kW
15
* CIMR-V BA0018 is available with a Heavy Duty rating only.

Drive Input Voltage Setting: E1-01

Set E1-01 according to the power supply voltage. This setting serves as a base value for
certain drive protective functions.
NOTICE: Set drive input voltage (not motor voltage) in parameter E1-01 for proper function of the protective
features of the drive. Failure to comply could result in improper drive operation. Set parameter E1-01 to
match the input voltage of the drive.
Parameter
Name
Input
E1-01
Voltage
Setting

Input Voltage Setting Value: E1-01

The input voltage level determines the overvoltage detection level and the operation level of
the braking transistor as shown in the table below.
Setting Value
Voltage
of
E1-01
200 V
all settings
Class
setting ≥ 400V
400 V
Class
setting < 400V
138
Three-Phase 200 V
Output
Model
Current
(Capacity)
(A)
2 0018
3.7 kW/
3.0W
17.5
2 0020
17.5
5.5 kW/
4.0 kW
14.0
Description
Set to the nominal voltage of the incoming line. Sets
the maximum and base voltage used by preset V/f
patterns (E1-03), and adjusts the levels of drive
protective features (e.g., overvoltage, braking
resistor level, stall prevention, etc.).
Braking
OV
Transistor
Detection
Operation
Level
Level
410 V
394 V
820 V
788 V
740 V
708 V
YASKAWA ELECTRIC TOEP C710606 09B YASKAWA AC Drive V1000 Installation & Start-Up Manual
Carrier
Output
Frequency
Current
(kHz)
(A)
2
17.5
8
14.0
15
11.2
2
19.6
8
17.5
15
14.0
(Approximate Values)
UV Detection Level
190 V
(single-phase=160 V)
380 V
350 V
Three-Phase 400 V
Carrier
Model
Frequency
(Capacity)
(kHz)
2
4 0009
3.7 kW/
8
3.0 kW
15
2
4 0011
5.5 kW/
8
4.0 kW
15
Setting Range
200 V Class: 155 to 255
400 V Class: 310 to 510
Voltage Level
Desired AC
Voltage
Suppression,
during KEB
Stall Prevention
240 V
480 V
440 V
Output
Current
(A)
8.8
7.2
4.3
11.1
9.2
5.5
Default
230 V
for OV
370 V
740 V
660 V

Hide quick links: