YASKAWA V1000 Series Installation & Start-Up Manual page 326

Compact vector control drive
Hide thumbs Also See for V1000 Series:
Table of Contents

Advertisement

B.2 Parameter Table
E: Motor Parameters
No.
Name
Input Voltage
E1-01
Setting
V/f Pattern
E1-03
Selection
326
Description
E1: V/f Pattern Characteristics
Use E1 parameters to set V/f characteristics for the motor.
This parameter must be set to the power
supply voltage. It sets the maximum and base
voltage used by preset V/f patterns (E1-03 = 0
to E) and adjusts levels used by certain
functions. Refer to page 130 for details
WARNING! Drive input voltage (not motor
voltage) must be set in E1-01 for the
protective features of the drive to function
properly. failure to do so may result in
equipment damage and/or death or personal
injury.
Selects a preset V/f pattern.
0: 50 Hz Constant torque 1
1: 60 Hz Constant torque 2
2: 60 Hz Constant torque 3 (50Hz base)
3: 72 Hz Constant torque 4 (60 Hz base)
4: 50 Hz Variable torque 1
5: 50 Hz Variable torque 2
6: 60 Hz Variable torque 3
7: 60 Hz Variable torque 4
8: 50 Hz High starting torque 1
9: 50 Hz High starting torque 2
A: 60 Hz High starting torque 3
B: 60 Hz High starting torque 4
C: 90 Hz (60 Hz base)
D: 120 Hz (60 Hz base)
E: 180 Hz (60 Hz base)
F: Custom V/f. E1-04 through E1-13 settings
define the V/f pattern.
YASKAWA ELECTRIC TOEP C710606 09B YASKAWA AC Drive V1000 Installation & Start-Up Manual
Control
Mode
Range
Def.
O
V/f
L
V
155 to
200 V S
S
255
A A −
0 to F
F
Addr.
Pg.
P
Hex
M
S
300
326
302

Hide quick links:

Advertisement

Table of Contents
loading

Table of Contents