Saving And Loading A Configuration Package File - AudioCodes Mediant 4000 SBC User Manual

Session border controllers
Hide thumbs Also See for Mediant 4000 SBC:
Table of Contents

Advertisement

CHAPTER 39    Configuration File
a.
Click the Browse button, and then browse to and select the file on your computer.
b.
Click the Load CLI Startup Script button; the following message box appears, informing
you that the device will reset after the file is loaded.
c.
Click Yes to continue (or No to cancel the file load). If you click Yes, the device loads the
file and then resets with a save to flash for the settings to take effect..

Saving and Loading a Configuration Package File

You can save and load a bundle of files used by the device in one single packaged file. The
packaged file is a TAR (Tape ARchive) file (.tar), compressed with gzip. The feature can be used
for backing up full configuration and then later restoring it to the device in case of device
configuration failure (for whatever reason), or for loading the backed-up configuration package file to
other devices requiring similar configuration.
The configuration package file can include the following files:
ini.ini (ini configuration file)
LOGO.dat (image file used as the logo in the Web interface)
FAVICON.dat (favicon file used for Web browsers)
CPT.dat (Call Progress Tone file) - present only if a CPT file was previously loaded to the
device
PRT.dat (Pre-recorded Tone file) - present only if a PRT file was previously loaded to the
device
AMD.dat (Answer Machine Detection file) - present only if a CPT file was previously loaded to
the device
SBC_Wizard.dat (SBC Configuration Wizard template file)
DPLN.dat (Dial Plan file) - only for backward compatibility of previous versions that supported
a Dial Plan file; for current versions, the Dial Plan is included in the ini file
Certificate files (<ctx_id>.crt, <ctx_id>.root, <ctx_id>.pkey)
DialPlanRule.csv (Dial Plan file) - present only if the device was configured with Dial Plan rules
When loading a Configuration Package file, the device needs to reset for the
settings to take effect.
For the certificate files, only the root certificate file (.root) can be saved.
When loading a Configuration Package file, the filenames must be as listed above.
By default, the Configuration Package file is saved with the filename
"ConfBackupPkg<Serial Number>.tar.gz".