CHAPTER 51    Reporting Information to External Party
Field
Redirect
URI
[804]
Release
Time
[413]
Remote
Input Octets
[614]
Remote
Input
Packets
[612]
Remote IP
[404]
Displays the original call redirect URI (username@host) after manipulation, if
any. The field value is a string of up to 150 characters.
Note:
The field is included in the default CDR.
The field is applicable to "CALL_END" CDR Report Types.
The field is applicable only to SBC signaling CDRs.
The default field title is "RedirectURINum".
The maximum number of characters for Syslog tabular alignment is 41.
Displays the date and time the call ended (disconnected). The field is a string of
up to 35 characters and presented in the following format: <hh:mm:ss:ms>
UTC <DDD> <MMM> <DD> <YYYY>. For example, "17:00:55.002 UTC Thu
Dec 14 2017".
Note:
To configure the time zone string (e.g., "UTC" - default, "GMT+1" and
"EST"), use the TimeZoneFormat parameter.
The field is included in the default CDR.
The field is applicable to "CALL_END" CDR Report Types.
The field is applicable only to SBC signaling and Gateway CDRs.
The default field title is "ReleaseTime" for Syslog, "h323-disconnect-time="
for RADIUS, and "Call End Time" in the Web SBC CDR History and Web
Gateway CDR History tables.
The maximum number of characters for Syslog tabular alignment is 35.
Displays the remote input octets (bytes).
Note:
The field is optional and can be included in the CDR using the Gateway
CDR Format and SBC CDR Format tables.
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The maximum number of characters for Syslog tabular alignment is 10.
Displays the number of packets that the remote side reported it received. The
field is an integer from 0 to 0XFFFFFFFF.
Note:
The field is optional and can be included in the CDR using the Gateway
CDR Format and SBC CDR Format tables.
The field is applicable only to "CALL_END" and "MEDIA_END" CDR
Report Types.
The field is applicable only to SBC media and Gateway CDRs.
The maximum number of characters for Syslog tabular alignment is 10.
Displays the remote SIP IP address.
Note:
The field is optional and can be included in the CDR using the Gateway
CDR Format and SBC CDR Format tables.