CHAPTER 60    Configuration Parameters Reference
SNMP Trap Destination Parameters
(configure system > snmp trap destination)
Note: Up to five SNMP trap managers can be defined.
'SNMP Manager'
[SNMPManagerIsUsed_x]
'IP Address'
ip-address
[SNMPManagerTableIP_x]
Parameter
- 872 -
Mediant 4000 SBC | User's Manual
Description
The ID can be a string of up to 36
characters. The default is
00:00:00:00:00:00:00:00:00:00:00:00 (12
Hex octets characters). The provided key
must be set with 12 Hex values delimited by
a colon (":") in the format xx:xx:...:xx. For
example,
00:11:22:33:44:55:66:77:88:99:aa:bb
Note:
For the parameter to take effect, a
device reset is required.
Before setting the parameter, all
SNMPv3 users must be deleted;
otherwise, the parameter setting is
ignored.
If the supplied key does not pass
validation of the 12 Hex values input or it
is set with the default value, the engine
ID is generated according to RFC 3411.
When the device operates in HA mode,
the parameter has the same value for
both active and redundant devices (i.e.,
system identifier). If the two devices
return to Standalone mode (i.e., non-HA
mode), you must configure the
parameter to a NULL value (i.e., no
value) for both devices. When the
devices reset to the Standalone mode,
each device automatically sets the
parameter to a unique value based on its'
serial number (S/N).
Determines the validity of the parameters
(IP address and port number) of the
corresponding SNMP Manager used to
receive SNMP traps.
[0] (Check box cleared) = Disabled
(default)
[1] (Check box selected) = Enabled
Defines the IP address of the remote host
used as an SNMP Manager. The device
sends SNMP traps to this IP address.
Enter the IP address in dotted-decimal
notation, e.g., 108.10.1.255.